ZDBI240WII – GE Monogram® Beverage Center
Dimensions and Specifications (in inches)
Installation Space
Side-by-Side Installation
For a complete refreshment center, install a Monogram Wine Reserve
and Beverage Center together.
The Monogram® Beverage Center may be installed beneath a
countertop or can be used free-standing.
• If installing between frameless cabinets, a 1/2"-wide filler strip
or side panel may be required. The filler strip will act as a spacer
between the door case and adjacent cabinet and will prevent
interference with cabinet door swing. The width of the opening
must include filler panels.
• Products must operate from separate properly grounded
receptacles.
Door Swing Clearances
All Monogram Refrigeration Modules are factory set for a 110°
door swing.
Note: When installed, the door should project forward 1" of
adjacent 24"-deep cabinets.
When installed in a corner:
• Allow the minimum door swing clearances shown.
• The minimum clearance shown at 90° will allow full extension
of drawers and shelves.
Locate Outlet
10-1/2"
10"
Minimum to Wall
23-3/4"
24" Min.
9"
Max.
34-1/2"-35"
1-1/2"
23-3/4" Min.
90° Door
Swing
110° Door
Swing
21-5/8"
34-1/4"
to
34-3/4"
23-5/8"
25-1/2"
Including
Handle
110°
90°
23-3/4"
4"
Minimum to Wall
Electrical
A 120V, 60Hz, 15 or 20 amp power supply is required. An individual
properly grounded branch circuit or circuit breaker is recommended.
Install a properly grounded 3-prong electrical recessed into the
back wall as shown. Electrical must be located on rear wall as shown.
Location Requirements
All Monogram Refrigeration Modules may be closed in on the top
and sides as long as the front is unobstructed for air circulation and
door swing.
Note: GFCI (ground fault circuit interrupter) is not recommended.
• Do not install these products where the temperatures will go
below 55°F (13°C) or above 90°F (32°C).
• Do not install where they will be subject to direct sunlight,
heat or moisture.
• These products are not designed to be stacked one over the other.
Listed by
Underwriters
Laboratories
®
For answers to your Monogram, GE Profile™ or
GE® appliance questions, visit our website at
GEAppliances.com or call GE Answer Center®
service, 800.626.2000.
Specification Created 10/07
120039
|
Conair Hair Dryer 124LR User Manual
Corinex Global IP Phone VoIP USB Phone User Manual
Craftsman Tiller 917293301 User Manual
Desa Tech Gas Heater CG2618PV User Manual
Dimplex Air Conditioner 6100770000 User Manual
Dimplex Fan KDS6401E User Manual
Electrolux Microwave Oven 267554 User Manual
Euro Pro Carpet Cleaner S3601CO User Manual
Faber Ventilation Hood INCA SMART User Manual
Frigidaire Ventilation Hood HV2730B User Manual